printable version
Technical data
Fastener Tightening
Name | | Value | | Cooling | Maximum cooling capacity (450 m3 / h) kcal / h | 4300 ?± 10% | | Power consumption | 252 | | Heating | The maximum heating capacity (270 m3 / h) kcal / h | 3900 ?± 10% | | Power consumption | 220 | | Compressor | Performance, cm 3 | 155.5 | | Maximum speed, min -1 | 9000 | | Grease, refer to 3 | 120 | | Receiver / dryer | Used dryer | CN - 9 | | Dual pressure sensor | High Pressure, kg / cm 2 | OFF: 32 DIFF: 6 | | Low pressure, kg / cm 2 | OFF: 2 DIFF: 0,25 | | Thread nozzles | High pressure | M10 x 1.25 | | Low pressure | 1,0 x M9 | | Refrigerant | Type | R134a | | Weight, g | 700 ?± 50 | Tightening torques, N ??? m
| Nuts of fastening of the fan unit / evaporator | 8 - 11 | | Bolts front of the air conditioner compressor bracket | 31 - 47 | | Bolts left side of the air conditioner compressor bracket | 16 - 23 | | Bolts compressor | 24 - 31 | | Bolts condenser fan | 8 - 11 | | Bolts condenser | 8 - 11 | | Nuts of fastening of the block heater | 8 - 11 | | Bolts receiver / dryer | 5 - 6 | | Bracket bolts receiver / dryer | 10 - 15 |
|