CAUSE   |   REMEDY   | 
  When vklyuchennomzazhiganii not illuminated battery charge indicator   | 
|   The battery is discharged  |   Charge the battery.  | 
|   The wires on the generator weakened or corroded  |   Check the contact wire, tightly tighten the bolt.  | 
|   Blown indicator battery charge  |   Replace the battery charge indicator.  | 
|   Faulty regulator  |   Check controller, replace if necessary.  | 
|   The break in the wiring between the generator-lock ignition switch, instruments and annunciator  |   Check the wiring with a voltmeter on the design of electrical equipment.  | 
|   Not inserted shtekkernye connection between the board of the rectifier and regulator tension  |   Remove the generator, if necessary, insert shtekkernye connectors.  | 
|   The carbon brushes are not adjacent to the contact rings  |   Check for ease of movement carbon brushes and the minimum length (5 mm).  | 
|   The generator field winding burned  |   Replace the rotor.  | 
  Do not go off indicator battery charge with increasing speed   | 
|   Loose V-ribbed belt  |   Tension the V-ribbed belt.  | 
|   Worn carbon brushes  |   Inspect the carbon brushes, replace if necessary.  | 
|   The regulator is faulty  |   Check controller, replace if necessary.  | 
|   Faulty line between the alternator and the regulator  |   Check the contact line and, if necessary, replace the wiring portion.  | 
  Lights switch charge the battery when the ignition is off   | 
|   Shorted diode positive  |   Check diodes and replace if necessary dildnuyu fee.  |