printable version
Removal, check and installation of the exhaust manifold and the exhaust system
| Fig. 2.173. The exhaust manifold and the exhaust system
|
Withdrawal
| Fig. 2.175. Removing the exhaust manifold assembly
|
Remove the exhaust manifold gasket.
Check Check exhaust manifold for cracks and damage. Using Rulers and feeler gauge, measure the warping of mating face of the exhaust manifold. Standard value: 0.15 mm. Limit: 0.30 mm.
Setting Install the exhaust manifold is made in reverse order of removal. Tightening torque of the mounting bolts of the exhaust manifold: M8 - 25-30 Nm M10 - 35-55 Nm.
ATTENTION Before replacing the exhaust manifold gasket replace the new one. Do not forget to install heat shields. |
|