Checking on the vehicle
Checking the battery charge indicator
Check current at the generator
Removing and installing the generator
Removal and installation of high-voltage wires
Starter
Lighting system
Screen wipers and washer
Immobiliser
The central panel and speakers
The instrument cluster and controls
Restraint System
Body
 


Hit Counter by Digits


print page printable version

Checking on the vehicle



Check the voltage at the terminals of the generator.
Make sure the battery is fully charged.
Make sure that the belt tension and deflection generator at the standard value.
Turn off all electrical consumers.
Turn the ignition switch to ?�START?� to make sure that the generator rotates uniformly and does not make noise during engine operation.

Connector Generator
Fig. 7.6. Connector Generator


Measure the voltage between the terminals of the generator (see. Fig. 7.6) at idle (at 20 ?� C) Table 7.1.
- Headlights;
- Electric fan heater;
- Rear window heater.
Make sure that the voltage at terminal ?�D?� generator is gradually increased.

Table 7.1 Check the voltage on the generator outputs
* Includes the following electricity consumers one by one: - lights;
- Electric fan heater;
- Rear window heater.