printable version
Anchor
Fasteners relays heating N 14
30 - terminal 30 continuous current 31 - Terminal 31, housing (-) 50 - terminal 50, the voltage by pressing the starter LA - terminal control bulb heating | 15 - terminal 15, the voltage when the ignition G1-G5 = connection glow 1-5 |
PERFORMANCE ORDER | 1. Connect a voltmeter between terminal 30 (A) plug relay control heating and housing. The meter should show the battery voltage (about 12 V). | | 2. Otherwise, check for an open red wire from the connecting block (X12 / 3) to the relay control heating. | 3. Turn the ignition key to the warm-up and connect a voltmeter to the chip 1 (terminal 15) 6-pin plug and the housing. Specification: battery voltage (about 12 V). If pressure is absent, check for an open black / red wire from fuse 23 (unprotected side) to the plug, 1 chip. | 4. Connect a voltmeter to the chip 1 (+ terminal 15) and the chip 4 (-, terminal 31). Specification: battery voltage (about 12 V). Otherwise, check for an open brown wire from 4 chips on the body. |
|
|