CAUSE | SOLUTION |
Do not rotate the fan heater |
Blown fuse of the fan motor. | Check the fuse of the fan, if necessary - replace. |
Defective fan switch. | Check the voltage supplied to the motor of the fan. If not, remove and check the circuit breaker. |
Faulty motor. | Replace the fan motor. |
Heating fan is not rotating at a speed steps |
Faulty additional resistance | Replace the additional resistance. |
Too small heating capacity |
Too low coolant level | Check the coolant level, if necessary - add coolant. |
Do not open the heating valve | Check the solenoid valve in the system water access, make passable. |
Leaking or clogged heat exchanger | Replace heat exchanger (Work for the repair shop). |
The heated air has a sweet smell, when the heating misted glass |
Leaking heat exchanger | Check the cooling system for leaks. Replace heat exchanger (Work for the repair shop). |
The noise when the fan heater |
Pollution fan | Remove the fan, clean the air channel. |
The imbalance of the impeller, bearing failure | Remove the fan motor and check for ease of rotation. |