printable version
Removal and installation of components of an inlet air path
Withdrawal The components of an inlet air path
Setting | | - Set the activator (1) the throttle valve to the upper cover (2) of the air cleaner. For this purpose the gasket (3) on the flange, and then the gasket (4) on the outer groove of the channel in the throttle valve with the top cover of the air cleaner, and finally tighten the screws activator. After disconnecting the electrical activator must be programmed closed throttle position and the idle position (see. Section Programming reference values for engine control).
|
| - Tighten the clamp bolts of covers of the air in the sequence shown in the illustration, first with a force 1.9 ÷ 2.2 N ??? m, and then with a force 3.8 ÷ 4.4 N ??? m.
|
- Install the air cleaner assembly of covers on the intake manifold, as described below in paragraphs 4-6.
| - Install the gasket (1) on the intake manifold and gasket (2) to channel PCV. The projection (4) on the body should enter the groove (3) on the gasket.
|
- Move the assembly covers the air cleaner to the intake conduit, while inserting the tabs at the back of the holes in the channel PCV the cylinder head cover.
| - Tighten the air cleaner cover bolts in the sequence shown in the illustration.
|
- Install the air cleaner housing with a filter element (see. Section Replacement of a filtering element of an air cleaner) and connect it to the air intake hose.
- Install e / m control valve Canister EVAP sensor and MAP. Make sure that the O-ring MAP sensor and mating surfaces are clean.
|
|
|
|