add to favorites contacts sitemap
REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Audi A6 (1997 release)

general info. full specifications. diagnostics. hints. tips. tricks
Audi A6
Home
 
Audi
A6
General Information
Operation of the vehicle
Maintenance
Engines
Ignition, fuel injection and exhaust of gasoline engines
The power supply system, and preheating the exhaust gases of diesel engines
Lubrication System
Cooling system
Coupling
Transmission
The front wheel drive shafts
Design features four-wheel drive transmission
Suspension
Wheels and tires
Steering
Brakes
Body
Heating and air conditioning
Electrical
Overview
General recommendations
Circuit breakers
Fuse
Electronic engine control unit
Accumulator battery
Generator
Removing and installing the generator at the non-turbo four-cylinder engines
Removing and installing the generator at the four-cylinder diesel TDI engine with distributor injection pump
Removing and installing the generator at the four-cylinder diesel TDI engine with unit injectors
Removing and installing the generator in the six-cylinder petrol engine
Removing and installing the generator for six diesel
Engine Starting System
Starter
Check and removal of the traction relay of a starter
Headlights
Replacement of lamps of external lighting
Engine corrector headlights
Front fog lights
Side repeater rotation
Back light
High level brake light
Replacement lamps auxiliary lights
Device combination
Cylinder ignition
Egnition lock
Switches of the central section of the instrument panel
Switch the heater front seats
Switches the rear section of the center console
The switch of external illumination
Switch adjustment of the rear-view mirror
Window switches on the driver
Radio
Speakers front / back door
Rear Defrost
Electric schemes
 


Hit Counter by Digits


print page printable version

Removing and installing the generator at the four-cylinder diesel TDI engine with unit injectors



Withdrawal

Location indicator (probe) (1) oil level and engine cover nuts on the four TDI diesel engines with unit injectors
Fig. 18.16. Location indicator (probe) (1) oil level and engine cover nuts on the four TDI diesel engines with unit injectors


Remove the pointer (probe) 1 (Fig. 18.16) oil level of the guide tube.
Loosen the clamp on the lid.
Remove the nuts and remove the engine cover.
Move the pointer (probe) oil level in the guide tube.

The weakening of the tension of the V-ribbed belt on the four-cylinder diesel engine TDI with unit injectors
Fig. 18.17. The weakening of the tension of the V-ribbed belt on the four-cylinder diesel engine TDI with unit injectors


Allen wrench, turn counterclockwise V-belt tension mechanism, resulting in a release the tension and remove the belt from the generator (Fig. 18.17).
Loosen the belt tensioner.

Disconnecting pulley radiator fan with viscous coupling to the four-cylinder diesel engine TDI with unit injectors
Fig. 18.18. Disconnecting pulley radiator fan with viscous coupling to the four-cylinder diesel engine TDI with unit injectors: 1 - Allen wrench 8 mm; 2 - a key 3212


Hold down the key from the crank pulley 3212 radiator fan with viscous coupling, 1 socket wrench 8 mm (Fig. 18.18) remove the pulley from the bracket.
Remove the radiator fan with viscous coupling.

Location terminals (1) and the electrical connector (2) for wiring to the alternator in the four-cylinder diesel engines
Fig. 18.14. Location terminals (1) and the electrical connector (2) for wiring to the alternator in the four-cylinder diesel engines


Remove the nut and disconnect the wire from terminal 1 (see. Fig. 18.14) generator.
Disconnect the electrical connector from the generator 2.
Take away from the generator lines and hoses.

Arrangement of bolts of fastening of the generator to the four-cylinder diesel engine TDI with unit injectors
Fig. 18.19. Arrangement of bolts of fastening of the generator to the four-cylinder diesel engine TDI with unit injectors


Unscrew the bolts (Fig. 18.19) and remove the generator.

Setting
Installation is spent to sequences, return to removal, taking into account the following.
Check the location of the V-ribbed belt on pulleys.
Tighten the generator torque 25 Nm.
Tighten the pulley bolt to the radiator fan bearings the moment of 45 Nm.
Tighten the screws fixing the wires to the terminal "30 / B +?� 16 N ?� m, to the terminal ?�D +?� - 4 N ?� m.