Adjusting the level of refrigerant
When replacing components other than the compressor | - To adjust the amount of refrigerant after replacing the evaporator, condenser or receiver-dryer, add compressor oil amount equal to the amount of refrigerant and deflated respectively 35, 15 or 5 cm 3. When replacing two or more components are added together only additional amounts, but amounts of refrigerant deflated.
|
|
When replacing the compressor | | - Drain compressor oil from the ports of high and low pressure compressor removed and measure the amount of oil.
|
- Drain the oil from the new compressor capacity (A), calculated according to the formula A = 60 - B - C. In this formula, B is the amount received in the previous paragraph, and C is the amount of oil released from the system with the refrigerant in the discharge system.
|
|
|