1. Turn the roll of the distributor so that the movable contact stood on the ledge of the cam roller. At the same time the gap between the contacts is a maximum. | 2. Measure the gap between the probe contacts 7 and 8 (see. Fig. The ignition distributor). It should be equal to 0.4 mm. The probe should be held between the contacts with a barely noticeable effort, in any case, the probe should not push pins. | 3. If the clearance is different from said adjust it. To do this, loosen the screws that secure the pin 8, insert a screwdriver into the slot contact 8 and turning it, thereby averting or summing pin 8 to pin 7, adjust the clearance. | 4. When adjusting UZSK or gap between contacts is broken ignition timing, so after adjusting UZSK clearance or need to adjust the ignition timing. |
|