1. Disconnect high voltage wires from the distributor cap. |
2. Remove the display 21 (see. Fig. The ignition distributor). |
3. Detach the spring 11 and remove the cover 1. |
4. Remove slider 3 and 4 anti-dust screen. |
5. Loosen the screws 5 and 6 to remove the cover. |
6. Watch contacts at a time as an assistant to the starter. If a contact is a strong spark, the capacitor 9 is defective and must be replaced. Between contacts of the breaker should slip some faint spark. |
7. Remove the movable contact 7 viewing. If the contact is light blue burn marks, then faulty capacitor. If traces of gray or black, it is the norm. In the case of a large metal transfer from one contact to another to clean up his velvet needle files. After cleaning rinse the contacts with gasoline. When stripping is necessary to remove hump on the fixed contact. Must completely crater on the movable contact is not recommended. Contacts should be adjacent to each other across the surface. |
8. Install the removed parts. |