If the engine is cold starts with difficulty, perhaps the device is heating the intake air. The work of this unit can be checked as follows: - Remove the pipe feeding the heated air;
| Fig. 117 Notes to the verification of heating the intake air: 1 - the position of the regulating valve during the overlapping stream of warm air; 2 - position of the flap at an outdoor temperature of -20 to + 22 ?� C
|
- Check the position of the progress and freedom of the regulating flap in the air filter housing (see. Fig. 117). At temperatures over 22 ?� flap should cover the warm air duct (pos. 1). At a temperature of -20 to + 22 ?� C flap to be opened by not more than 2/3 (pos. 2). You can check and thermocouple work, but it requires a special refrigerant spray. If you put spray on the thermocouple, the regulating valve should open access to warm air; - The work of a damper must be checked. To do this, pull the short rubber tube to the nozzle of a vacuum hose attachment and podsasyvaya air from the hose, check whether the butterfly valve; - Re-establish the vacuum hose, securing the safety clip; - Disconnect the vacuum hose from the thermostat the injector. Regulating throttle after about 20 seconds should regain its original position.
|