printable version
System of cooling, heating, ventilation and air conditioning
Specifications Cooling system Common parameters Cooling system | Closed, pressurized (water pump), thermostat, radiator, fan (with a belt drive and viscous clutch) and separately installed expansion tank |
The volume of coolant | See. Specifications to the Head Current leaving and service | The composition of the coolant (antifreeze proportion of coolant for frost / specific gravity at 20 ?� C) | up to -16 ?� C
| 35% / 1.054 | to -26 ?� C
| 45% / 1,066 | to -40 ?� C
| 55% / 1,078 | Operating pressure in the system pressure (kPa) | 1.05 (103) |
Thermostat Type (all models) | Voskozapolnenny, two-step | Full speed valve (see. mm | - The main valve (all models)
| 8 | - Additional valve (all models)
| 15 | Valve activation temperature, ?� C | | | - The main valve (all models)
| 88 + 1 | - Additional valve (all models)
| 85 +2 | | 100 | Diesel models | | - The main valve (all models)
| 88 +1.5 | - Additional valve (all models)
| 80+ 1.5 | | 100 |
Heating, ventilation and air conditioning Heating / ventilation of salon The type and amount of the working fluid | See. Specifications to the Head Routine maintenance and servicing (cooling system) | Control | Electronic | The maximum heating capacity kcal / h | 3800 | Air flow, m3 / h | 270 | Power consumption of the fan W | 250 |
The system K / V The type and amount of refrigerant | See. Specifications to the Head Current leaving and service | The type and amount of refrigerant oil | See. Specifications to the Head Current leaving and service | Control | Electronic | The maximum cooling capacity of the system K / V, kcal / h | 4200 + 10% | Refrigerant pressure, kgf / cm2 | | 15.0 ÷ 17.0 | | 1.3 ÷ 2.0 | Air flow, m3 / h | 440 | Power consumption of the fan W | 250 | Compressor | | Rotary vane, Zexel | | 155.3 | | 9000 | | Magnetic | | 40 (12) | Capacitor | PF COND | | Receiver Drier | | | ZEOLITE | - The amount of desiccant, Mr.
| 35 | Evaporator | | | Plate with expansion valve locking type |
Efforts of a tightening of carving connections, Nanometer  | Efforts of a tightening of certain fastener elements can be shown directly in the section where they are highlighted in bold. |
Cooling system Nuts of fastening of the thermostat | 22 | Bolts of a cover of the thermostat | 22 | Bolts intake | 10 | Bolts expansion tank | 10 | Bolt fan clutch | 76 | Bolts impeller | 37 | Bolts pulley fan | 21.5 | Bolts of the exhaust manifold and intake manifold with mounting brackets | 24 | Bolts starter and the support bracket | 47 | Bolt support bracket tube heater | 22 | Bolts and nuts thermoprotective screens | 22 | Tie clip bolt wiring | 22 | Timing cover | 8 | Bolts of fastening of the water pump | 22 | Timing belt tensioner bolt | 43 | Bolt intermediate roller | 22 |
Heating / ventilation / air conditioning Bolts / nuts fan heater | 9 | Bolts service cover for the engine compartment bulkhead (see. | 9 | Bolts finishing sections of the instrument panel | 9 | Bolts glovebox | 9 | Bolts compressor | 24 | Nut belt tensioner pulley | 24 | Bolts anther lower engine protection | 8 | Flare nut connection to the compressor refrigerator lines | 24 | Bolts fan K / V | 9 | Bolts capacitor | 9 | The socket connectors connected to the condenser refrigeration hoses | 13 and 22 | Bolts exchanger heater | 9 | Flare nut evaporator lines | 13 and 32 | Fixing choke connector evaporative line to the engine compartment bulkhead | 24 | Nuts of fastening of the receiver-dryer | 9 | The socket connectors connecting refrigerator lines to the receiver-dryer | 13 |
|