| Kia |  | Sportage | | Introduction | | Controls and operation receptions | | Current care and maintenance | | Engine | | System of cooling, heating, ventilation and air conditioning | | general information | | Engine cooling system | |  | Ventilation systems, heating and air conditioning | | | General information and safety measures | | | Troubleshooting, check the system components K / | | | Removal and installation of assemblage blower / evaporator service components | | | Removal and installation of the heater assembly, maintenance components | | | Removal and installation of communication lines refrigerator path of K / | | | Removal, check and installation of compressor K / V | | | Removal, check and installation of the fan of the condenser K / V | | | Removal, check and installation of the condenser K / V | | |  | Removal, check and installation of the receiver-dryer | | The power supply system, motor control / emission control and exhaust | | Systems of an electric motor | | A five-speed manual gearbox gear | | Automatic Transmission | | Transmission Line | | Brakes | | Suspension and steering | | Body | | Onboard electric | | The control body dimensions | |  | Wiring | | |
|
|
|
printable version
Removal and installation of assemblage blower / evaporator service components
Withdrawal Service components | - Visually vote outside the state assembly blower / heater.
|
|
Relay blower Arrangement of contact terminals in the connector blower relay (terminal ?��3 - ground) | - Disconnect the relay blower wiring.
- Apply a voltage of 12 V at terminals ?��?�� 5 () and 3 (-) relay and make sure available conductivity between plugs ?��?�� 1 and 2. If conductivity is absent, replace the relay.
|
|
Control relay activation and shutdown K / Arrangement of contact terminals in the connector control relay activation and shutdown K / V (terminal ?��3 - ground) | - Disconnect the electrical wiring from the relay.
- Apply a voltage of 12 V at terminals ?��?�� 1 () or 3 (-) relay and make sure available conductivity between plugs ?��?�� 2 and 4. If conductivity is absent, replace the relay.
|
|
The electric motor drive blower | - Disconnect the engine wiring harness.
- Make sure of serviceability of functioning of the electric motor when power is applied to the terminals 12 ?��?�� 2 () 1 (-) connector. At negative result of check replace the electric motor.
|
|
Resistive assembly motor drive blower | - Disconnect from the resistive wiring assembly.
| - Measure the resistance between the contact terminals of the connector assembly of resistive. If the measurement results differ from the desired values, replace the assembly predrezistorov.
|
|
|
The servo valve inlet | | - Make sure of serviceability switching damper in fresh air mode when applying for plugs ?��?�� 4 () and 6 (-) voltage of 12 V. Activation of circulation must occur at a grounding terminal number 3 slot.
|
- Faulty actuator must be replaced.
|
|
Termorazem Setting | - Installation is the reverse order of dismantle of components. Ensure compliance with the requirements of the specification of the Head of System of cooling, heating, ventilation and air conditioning systems to the efforts of a tightening of threaded fasteners.
- Finally, do not forget to recharge the A / C service by a qualified professional service center.
|
|
|
|