CAUSE | REMEDY |
When vklyuchennomzazhiganii not illuminated battery charge indicator |
The battery is discharged | Charge the battery. |
The wires on the generator weakened or corroded | Check the contact wire, tightly tighten the bolt. |
Blown indicator battery charge | Replace the battery charge indicator. |
Faulty regulator | Check controller, replace if necessary. |
The break in the wiring between the generator-lock ignition switch, instruments and annunciator | Check the wiring with a voltmeter on the design of electrical equipment. |
Not inserted shtekkernye connection between the board of the rectifier and regulator tension | Remove the generator, if necessary, insert shtekkernye connectors. |
The carbon brushes are not adjacent to the contact rings | Check for ease of movement carbon brushes and the minimum length (5 mm). |
The generator field winding burned | Replace the rotor. |
Do not go off indicator battery charge with increasing speed |
Loose V-ribbed belt | Tension the V-ribbed belt. |
Worn carbon brushes | Inspect the carbon brushes, replace if necessary. |
The regulator is faulty | Check controller, replace if necessary. |
Faulty line between the alternator and the regulator | Check the contact line and, if necessary, replace the wiring portion. |
Lights switch charge the battery when the ignition is off |
Shorted diode positive | Check diodes and replace if necessary dildnuyu fee. |