add to favorites contacts sitemap
REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Mercedes-Benz E-Class

general info. full specifications. diagnostics. hints. tips. tricks
Mercedes-Benz E-class
Home
 
Mercedes-Benz
E-class
Introduction
Description of the model Mercedes E-Class
Working conditions and tools
Car Care
Diesel engines
Petrol engines
Transmission
Chassis
The brake system
Electrical
Accumulator battery
Starter
Generator
Checking the level of electrolyte in the battery, service contacts.
Checking the battery charge
Start the engine from the external power supply
Charging the battery
Removing the battery
Detection of faulty consumer
Checking the voltage regulator
Removing the generator
Removing and installing starter
Lighting
Sound and light alarm
Control equipment
Device combination
Cruise control (cruise control)
The system of airbags and seat belt pretensioners
Wires and fuses
Cable colors
Mounting block relays and fuses
Circuit breakers
Electrical circuits
Shop
Body
Applications
Diagrams
 


Hit Counter by Digits


print page printable version

Removing the generator



SEQUENCE OF WORK
Withdrawal
1. Remove the wire from the negative terminal of the battery.

A WARNING
When disconnecting the battery is erased memory (eg radio code) of the electron-storage devices.

2. Loosen the accessory drive belt and remove from a generator pulley. On cars with a V6 or V8 engine, remove the fan with viscous coupling. Loosen the fastening of the generator to the engine, while the last turn away a bolt from the pulley on the left.
3. Remove the generator is more convenient from below the car, so make sure you pick up the car.
4. Remove the lower engine protection.
5. Remove the protective cover from the back of the generator, turn beneath the contact connection.
6. Do not forget the wire of "weight."
7. Unscrew and remove the upper and lower mounting bolts of the generator. Tightening torque for reassembly 42 Nm.

After removing the retaining pins from the generator engine compartment easier to remove from the bottom (diesel engine)
Fig. 9.12. After removing the retaining pins from the generator engine compartment easier to remove from the bottom (diesel engine)


8. Pull down the generator (Fig. 9.12).

PRACTICAL ADVICE
Stir with a faulty generator
If the alternator or voltage regulator out of order, it is nevertheless possible to continue the movement. To provide consumers with energy to a rechargeable battery. Depending on the battery capacity and battery power should last for about 5 hours (unless, of course, do not include powerful consumers).
1. Unplug the power generator to the battery is not discharged through the faulty generator or regulator.
2. No need to try to stop. Especially a lot of energy is consumed by the starter. If possible, move coasting.
3. Do not turn the heated rear window, a fan and a radio.
4. Windshield wiper and washer switch only when necessary.
5. In the dark as much as possible, do not use high beams and fog lamps.