1. Set the starter and secure with nuts, having tightened their moment of 60 Nm. |
| 2. Connect the cable to terminal 30 (1) and tighten the nut to 13 Nm wire (2 - 50 Terminal 3 - terminal 15A, 4 - Connection of the field winding starter). |
3. Connect the electrical connector terminal 50 starter (3). |
4. Secure the bracket to the coolant pipe. |
5. Establish the bottom mudguard of a motor compartment. |
6. Connect the ground cable to the battery. |