1. In case of refusal or abuse of serviceability of functioning of the fan heater, first check the condition and attachment of terminal connections corresponding circuit. Make sure in the fullness of the battery. Assess the corresponding fuse, relay switch. There is also the probability of failure of the drive motor. 2. Before proceeding to the verification of the actual motor will appreciate the condition of fuse and relays (if applicable) (see chap. Onboard electric equipment). 3. In order to ensure access to housing heater and fan assembly, remove the glove box and the lower section of the instrument panel trim (see chap. Body). | 4. Turn the ignition key to the ON position and set the fan control switch heater exemption provision (s). To check the functioning of the power supply to the motor will need lamp or voltmeter probe. If voltage is applied correctly, check the condition of the ground circuit of the motor (on the models under consideration control switch and resistor assembly is part of the ground circuit). There is also the chance of jamming the impeller. |
5. To check the quality of the grounding, disconnect the motor wiring and connect the jumper wire between the ground terminal of the motor and a good ground. The second jumper wire to connect the positive terminal of the motor and the battery. If the fan starts to rotate properly, it is a violation of the quality of the ground or out of service resistor assembly. Otherwise, replace the motor, or eliminate the cause of jamming the impeller. 6. To identify the causes of jamming the impeller assembly, remove the electric motor (see. Section Removal and installation of an electric motor driving the fan heater). | 7. If any of the quality of ground Check the condition of the resistor assembly disposed in the housing adjacent to the electric motor. |
8. Use an ohmmeter to check the quality of the grounding resistor assembly in various positions of the switch control - in every position (except OFF) conductivity should take place between the three terminals of six. 9. In case of violations should produce appropriate refurbishment of switch or wiring running to his chain. 10. If a properly grounded, check Resistor network for the presence of the conduction between the terminals. in case of breakage, replace the resistor. 11. Description of procedures for checking the functioning of pereklchyuatelya select fan speed modes, see. Section Removal and installation of assemblage of the control panel operation of heater and air conditioner, adjustable drive cable. In order to access the control panel, remove the functioning of a heater / air conditioner of "Torpedo". 12. Disconnect electrical wiring and use an ohmmeter to check the distribution of the conduction between the connector terminals pereklchyuatelya. | |
13. In case of violations, replace the switch. |