- Uncover the carburettor.
- Remove the bracket and remove the float and needle valve.
- Install the new float and needle valve and fix their guard.
- Set 13 caliber 1070.
- Lift the float until resistance; wherein the needle valve has to be sunk. In this position, the heel of the caliber must be aligned with the upper edge of the recess of the float.
- If necessary, bend the tab of the float.
- If the gauge is not, adjust the level of fuel in the float chamber as follows:
- Remove the cover from the carburetor gasket and lock the axis of the float, so it does not rise;
- disconnect the wires from the ignition coil and fill the float chamber fuel with the engine starter;
- measure the distance between the level of the plane of the connector and the fuel of the float chamber, which should be in the range of 7 ?� 1 mm with a cover of the carburettor;
- In the event of adjustment make podgibaniem tongue float.
|
|