Checking gap "A" between the edges of the plunger and aperture actuator additional starting device
1 - the adjusting screw
PERFORMANCE ORDER
Check the gap "A" between the edges of the plunger and aperture actuator additional starting device for a coolant temperature of 20 ?� C, which should be in the range 2.0-2.2 mm.
If the size is not correct, adjust the screw 1, the pre-actuator plunging additional trigger device in a tank of water heated to 20 ?� C.