Storage Battery
The batteries are not used for a long time, discharge by themselves and can be susceptible to sulfation. If such a battery quick charger to charge, they do not accept the charging current, and because of the so-called surface charge is "total" too early. They have failed. | - Before you reject the battery, you should check it.
- Check the density of the electrolyte. If the density of all banks do not differ by more than 0.04 g / ml, the battery should be charged normal charger.
- Check battery after charging under load. If the values do not match the required, the battery is faulty.
- If the density of the electrolyte in one or more banks are significantly lower than the others (for example, 5 banks density is 1.16 g / ml and a 1.08 g / ml), the battery has a short circuit.
- To avoid premature aging of the battery must be recharged stored battery every 2 months.
|
|
|